Sign In | Join Free | My himfr.com
Home > Automatic Water Cannon >

Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF

    Buy cheap Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF from wholesalers
     
    Buy cheap Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF from wholesalers
    • Buy cheap Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF from wholesalers
    • Buy cheap Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF from wholesalers
    • Buy cheap Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF from wholesalers
    • Buy cheap Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF from wholesalers
    • Buy cheap Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF from wholesalers

    Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF

    Ask Lasest Price
    Brand Name : LinkZone
    Model Number : ZDMS 0.8/20S-LZ II-Ex
    Supply Ability : 200000 Set/Sets per Year
    Price : $4,300.00 - $4,500.00/sets
    • Product Details
    • Company Profile

    Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF

    fire protection system anti-explosion automatic tracking and positioning fire water cannon

    Product Overview

    INTELLIGENT FIRE MONITOR AUTOMATIC FIRE SPRINKLER SYSTEM
    Our intelligent fire monitor adopts infrared thermal imaging principle and air-to-air missile tracking technology,It has the functions of real-time measurement and calculation of the real-time temperature of the fire, automatic tracking of the fire, automatic spraying to extinguish, and automatic water shutoff after the fire is extinguished.
    FEATURES AT A GLANCE
    ITEM#:ZDMS 0.8/20S-LZ II-Ex
    DIMENSION:550×460mm
    NET WEIGHT:28KG
    SENSOR:IR SENSOR
    VOLTAGE:220V
    COMMUNICATION METHOD:CAN bus
    KEYWORD:INTELLIGENT FIRE WATER CANNON
    Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF
    Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF
    Front elevation
    Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF
    Left elevation
    Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF
    Front elevation
    PRODUCT SPECIFICATIONS
    No
    Item
    Standard &Requirements
    Inspection results
    1
    Rated working pressure (MPa)
    ≤0.8
    0.6
    /
    2
    Rated flow (L / s)
    20×(1±8%)
    20.1
    /
    3
    Maximum protection radius(m)
    ≥50
    50
    /
    4
    Jet radius (m)
    ≥55
    55
    /
    5
    Monitoring radius(m)
    ≥80
    80
    /
    6
    Positioning time(s)
    ≤60
    59
    60
    7
    Installation height (m)
    8~15
    8
    15
    8
    Horizontal swing angle(°)
    ≥180
    360
    9
    Minimum pitch profile(°)
    -90~+30
    -90~+30
    10
    working temperature
    4~55℃ ≤95%RH
    4~55℃ ≤95%RH
    11
    Guidance system
    Φ 15.5 ± 0.5
    Φ 15.5 ± 0.5
    PRODUCT CONFIGURATION
    Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF
    Control host
    Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF
    Electric control box
    Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF
    Field operation panel
    Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF
    SALES AND SERVICE NETWORK
    Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF
    Successful Project
    Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF
    Project in Malaysia
    Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF
    Project in Azerbaijan
    Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF
    Project in Singapore
    Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF
    WUHAN International airport
    Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF
    The people's hospital of JINING
    Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF
    HUANGGANG Rose Times Square
    FAQ
    Q1: Are you a manufacturer?
    A1: Yes. We are a professional manufacture of intelligent fire-fighting equipment, like Full-auto Fire Monitor|Intelligent Fire Water Cannon.
    Q2: What certificates do you have?
    A2: We only have CCC and ISO at present. FM or UL will be got within next year.
    Q3: What are the advantages of your Intelligent Fire Monitor|Fire Water Cannon?
    A3: Our Intelligent Fire Monitor|Fire Water Cannon integrates the following functions: 1. Remote Video Surveillance. 2. Fire Alarm. 3. Intelligent Fire Extinguishing.
    CONTACT
    Alex Zhang
    Sales Manager
    Henan Linkzone Fire Technology Co.,Ltd
    Add.:Room 602,Building 6,No.316, Lianhua street, High-tech Zone, Zhengzhou City, China
    Email:alexzhang@linkzonefire.net
    whatsapp:+8619836717667
    Quality Anti Explosion Automatic Water Cannon monitor Auto Tracking Positioning CCCF for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Henan LinkZone Fire Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)