    Brand Name : LinkZone
    Model Number : ZDMS0.6/5S-LZII
    Certification : CCCF
    Price : Negotiable
    Payment Terms : T/T, L/C
    Supply Ability : 2000sets per month
    Delivery Time : 5~8 work days
    • Product Details
    • Company Profile

    Accurate Aiming Automatic Fire Water Monitor With Flame Detector 20m 0.6Mpa


    Automatic Fire Water Monitor

    Features:

    ●Uninterrupted video monitoring.

    ●360° horizontal rotate and 120° vertical rotate.

    ●Large volume water discharge,quick response ,long jet distance and large protection range.

    Infrared thermal imaging detecting and tracking technology ensure no miss alarming and no fault alarming.

    ●Applicable voltage range:AC 110V~240V.

    ●Functions Integrated:Fire monitoring,Fire alarming and Fire extinguishing.

    ●Water saving,full sealed,easy to operate.

    Remote control and automatically scanning.

    Description:

    Our Automatic Fire Water Monitor discharge large volumes of suppression agent from a single fixed location, and at high pressure to give it an excellent range of coverage.The Quick Response Fire Fighting Monitor has built-in infrared thermal imaging detector, UV flame detector, closed circuit television camera. Real time dynamic flame location and laser corrector. The Automatic Fire Water Monitor works with the external UV flame detector to eliminate the detection blind area and increase early warning range.


    When the Automatic Fire Water Monitor receives the fire early warning signal (UV or IR signal),it's built-in image IR flame detector will automatically rotate along with the water monitor and tracking the flame for 3 seconds, then spray water to extinguish the fire. Otherwise, the water monitor will consider it as a false alarm, and the Automatic Fire Water Monitor will reset automatically.The time spent from fire started to fire targeted is less than 30 seconds.

    Accurate Aiming Automatic Fire Water Monitor With Flame Detector 20m 0.6Mpa


    Specifications:

    ZDMS0.6/5S-LZIIZDMS0.6/10S-LZIIZDMS0.8/20S-LZIIZDMS0.9/30S-LZIIZDMS0.8/40S-LZIIZDMS0.8/50S-LZII

    Working Voltage

    DC36VDC36VDC24VDC24VDC24VDC24V
    Rated Pressure0.6MPa0.6MPa0.8MPa0.9MPa0.8MPa0.8MPa
    Protection Radius20m28m42m50m52m55m
    Rate of flow5L/s10L/s20L/s30L/s40L/s50L/s
    Installation Height6~15m6~15m8~35m8~35m8~35m8~35m
    Jet radius34m39m56m62m67m73m
    Positioning time≤30s≤30s≤60s≤60s≤60s≤60s
    Monitoring radius40m40m60m60m80m80m
    Flange ConnectionDN50DN50DN80DN80DN100DN100

    Notices:

    1.The side of cannon with label”this side to wall” must be faced to wall when installed.
    2.Video line connected from DVR to cannon directly.
    3.Signal lines must connect to signal lines of cannon where it is 2m from cannon.
    4.Operation panel installed near the exit and 1.5m from ground,and from where operator can see all cannnons controlled by this operation panel.
    5.Pls take care when handling cannon as there is UV detector at the bottom of cannon.The UV detetor is fragile.
    6.Make sure there is no barrier around the cannon to stop the cannon 360 degree rotate.
    7.The ground lead of DVR,earth wire and Lightning protection wire of control console need be connected to your ground lead.


    Applications:

    Our Automatic Fire Water Monitor are wildly used in Industrial,commercial and residential fields.Such as airport, high-speed railway station, bus station, hotel atrium, museum, library, TV studio, gymnasium, science and technology museum, exhibition hall, convention center, theater, cinema, civic activity center, industrial plant, chemical plant, gas station, oil port,helicopter hangar, power plants, logistics centers, hospitals, large shopping malls, commercial complexes, colleges and universities, coal mines, warehouses and other places with large space.

    Accurate Aiming Automatic Fire Water Monitor With Flame Detector 20m 0.6Mpa

    FAQ:

    Q1: Are you a manufacturer?

    A1: Yes. We are a professional and No.1 manufacture of Automatic Fire Water Monitor which has the most advanced technology.
    Q2: What certificates do you have?
    A2: We only have CCCF and ISO certificate at present. And we plan to do FM certificate later.
    Q3: What are the advantages of your Automatic Fire Monitor?
    A3: Our Automatic Fire Monitor adopt the Infrared thermal imaging detecting and targeting technology. Our Fire Water Cannon integrates the following functions: 1. Remote Video Surveillance. 2. Fire Alarm. 3. Intelligent Fire Extinguishing.
    Contact:
    Alex Zhang
    Sales Manager
    Henan Linkzone Fire technology Co.,Ltd
    Add.:Room 602,Building 6,No.316 Lianhua Road, High-tech Zone, Zhengzhou City, China
    Email:alexzhang@linkzonefire.net
    whatsapp:+86 19836717667
    Wechat:alex19836717667
    Website:www.linkzonefire.com
    Website:www.automaticfiremonitor.com

    Quality Accurate Aiming Automatic Fire Water Monitor With Flame Detector 20m 0.6Mpa for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Henan LinkZone Fire Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)